Services  →  Cooling Systems

Council · Hospitality · Worksite · Public Realm · Australia-Wide

Outdoor Cooling Systems
That Actually Work
in Australian Heat.

High-pressure misting systems that reduce ambient temperatures by up to 12°C, without wetting surfaces or requiring expensive infrastructure. For councils, venues, worksites and public spaces.

✓ Up to 12°C Reduction ✓ Non-Wetting Mist ✓ Automated Controls ✓ WHS Compliant
Trusted by leading government, civil and industrial organisations across Australia
How It Works

The Science of
Evaporative Cooling.

A youmist high-pressure system forces water through specially engineered nozzles at over 1,000 PSI, atomising it into ultra-fine droplets of just 5–10 microns. Droplets this small don't wet surfaces. Instead, they flash-evaporate on contact with hot air, absorbing heat energy from the surrounding environment and reducing the ambient temperature by up to 12°C.

The result is a cooling effect that's immediate, comfortable and safe around people in parks, playgrounds, restaurants, event spaces and worksites. No air conditioning infrastructure. No wet surfaces. No runoff.

12°C
Maximum Temperature Reduction

5–10
microns · Average Droplet Size

< $3.50
Per day in power and water

Based on standard single-phase pump installation

System Types

The Right System
for Every Space.

Every youmist cooling system is custom-designed for the specific space, structure and usage pattern. These are the six system configurations we work with most often.

Fixed perimeter misting lines at outdoor venue
01
Fixed Perimeter Lines

The most common installation for pergolas, trellises, alfresco areas and outdoor dining. Stainless steel or PA12 misting lines installed along the perimeter or overhead structure, discreet, reliable and effective for defined outdoor spaces.

Best for: Hospitality venues · Pergolas · Covered public areas
Misting fans at outdoor venue
02
Misting Fans

High-pressure misting combined with industrial fan projection, cooling reaches up to 10 metres from the unit. Effective for large open industrial and commercial spaces without fixed infrastructure.

Best for: Warehouses · Industrial yards · Construction sites
Cooling station at Canley Vale Park
03
Cooling Stations

Freestanding high-pressure cooling stations for parks, playgrounds and public spaces. Self-contained units with built-in pump, filter and controls, no fixed infrastructure required. Ideal for councils needing flexible, relocatable cooling.

Best for: Council parks · Playgrounds · Public events · Aquatic centres
Flush-mount ground misting system in public precinct
04
Flush-Mount Ground Systems

Nozzles set flush with concrete, pavers or decking, zero above-ground footprint. Mist rises from the ground surface creating a dramatic cooling and visual effect. Specified by landscape architects for high-traffic public precincts.

Best for: Civic precincts · Government facilities · Public plazas
Catenary line misting system over outdoor dining
05
Catenary Line Systems

Spanning wire systems for large open areas with no overhead structure. Nozzles hang from stainless catenary lines strung between posts, covering areas of 100m² to 1,000m²+. 230+ nozzle configurations available.

Best for: Parks · Playgrounds · Town squares · Event spaces
HVAC condenser pre-cooling misting system
06
HVAC Pre-Cooling & Condenser Assist

High-pressure misting arrays installed at condenser coil inlets, chiller intakes and cooling tower air entry points. Reduces inlet air temperature by up to 12°C, improving HVAC coefficient of performance and cutting energy consumption by up to 25% during peak summer load. Also used for exhaust plume suppression.

Best for: Data centres · Shopping centres · Commercial towers · Hospitals · Industrial refrigeration

Proof of Work

See Our Installations in Action

Visit Our Featured Projects
Industries & Applications

Eight Types of Space.
One Specialist Team.

01
Council Parks & Playgrounds

Temperature-triggered misting keeping public spaces usable and meeting council duty-of-care obligations.

02
Public Precincts & Town Centres

Landscape-integrated cooling for civic precincts, high streets and public realm activations.

03
Outdoor Hospitality Venues

Alfresco dining, beer gardens and outdoor event spaces. Extend your revenue season by making outdoor areas comfortable in summer.

04
Aquatic Centres & Leisure

Entry areas, spectator seating and outdoor recreation zones at aquatic and leisure facilities.

05
Outdoor Worksites & Construction

WHS Act heat stress compliance for outdoor workers, cooling for site sheds, break areas and exposed work zones.

06
Warehouses & Industrial Yards

Misting fans and perimeter systems for loading bays, processing areas and outdoor yards.

07
Schools & Childcare Centres

Safe, non-wetting cooling for playgrounds and outdoor learning areas, automated operation.

08
Sporting Venues & Stadiums

Spectator cooling, player warm-up areas and outdoor function spaces at sporting venues.

Need to Cool an Outdoor Space?

Tell us your site and we'll recommend the right system within one business day.

Send an Enquiry →
12°C
Temperature Reduction

Up to 12°C ambient cooling in direct mist zone

Non-Wetting
No wet surfaces or runoff

Droplets evaporate before reaching surfaces

Automated
Temperature or timer triggered

No manual switching or oversight needed

WHS
Heat stress obligations

Documented for WHS Act compliance

Landscape
Integrated
Blends with any structure

Stainless steel or PA12, discreet installation

< $3.50/day
Power and water cost

Based on standard single-phase installation

Opera Bar Sydney Harbour misting installation
Case Study · Outdoor Hospitality · Sydney Harbour

Opera Bar
Sydney Harbour

City of Sydney · Commercial Venue

One of Sydney's most iconic outdoor hospitality venues required a discreet cooling solution that would complement the harbour setting without compromising the venue's aesthetic. youmist installed high-pressure tubing and nozzles around the perimeter of all the structural umbrellas across the full alfresco area.

The system delivers multiple benefits simultaneously: ambient cooling for diners, fly repellent through the continuous fine mist barrier, and bird deterrent keeping seagulls and ibis away from the dining area. All without wetting surfaces or affecting the dining experience.


  • City of Sydney specification met
  • Cooling, fly repellent and bird deterrent in one system
  • Extended outdoor revenue season through summer
  • Non-wetting mist, safe for diners and surfaces
Westpoint Playground outdoor cooling system
Case Study · Council Playground · Western Sydney

Westpoint Shopping Centre
Outdoor Playground

Blacktown City Council · Western Sydney

An outdoor playground at one of Western Sydney's major shopping centres required a cooling solution that would keep children safe and comfortable during hot summer days, extending usable hours and reducing heat stress risk for families. youmist installed a catenary line misting system across the playground area, nozzles suspended from stainless wire spanning the full play space, activated automatically when temperatures reach threshold.


  • Full playground area covered
  • Temperature-triggered automatic operation
  • Non-wetting mist with no slip hazard
  • Extends usable hours through summer
Moore Plains Shire Council public trellis cooling installation
Case Study · Council Public Space · Regional NSW

Moore Plains Shire Council
Public Town Centre Trellises

Moore Plains Shire Council · Regional NSW

The town centre of Moore features a series of public trellises providing shaded community rest areas throughout warm months. Council engaged youmist to design a cooling solution that would reduce temperatures, eliminate manual operation, prevent theft or damage, and improve air quality in the dry regional heat. youmist installed the Polaris Series cooling system across six large trellis spaces, four single-phase high-pressure pump units with ultra-mist nozzles, activated automatically at 32°C.


  • Automatic activation at 32°C threshold
  • Under $3.50/day in power and water
  • Six large public spaces covered by four pump units
  • Temperature reduced and businesses extended outdoor trade
HVAC Pre-Cooling & Condenser Assist

Your HVAC Is Working
Harder Than It Should Be.

On a 40°C summer day, your condenser is drawing in the hottest air of the year, at exactly the moment it needs to work hardest. Every degree of inlet air temperature above design spec costs you efficiency, capacity and energy. A youmist pre-cooling system fixes that problem at the source.

Up to 12°C
Reduction in condenser inlet air temperature
Up to 25%
Improvement in HVAC efficiency during peak load
1°C = 3%
Every degree of inlet air reduction improves COP by approximately 3%

How It Works

High-pressure misting nozzles are installed at the air intake of your condenser coils, chillers or cooling tower louvers. Ultra-fine 5–10 micron droplets are introduced into the incoming airstream, evaporating before they contact any surface, cooling the air without wetting coils or components.

The result is a meaningful reduction in the temperature of air entering the condenser, improving the coefficient of performance (COP) of your HVAC system and reducing the compressor load during the hottest periods of the year, when energy costs are highest and capacity is most constrained.

Applications

  • Condenser coil pre-cooling
  • Chiller intake air cooling
  • Data centre cooling tower assist
  • Exhaust plume suppression
  • Large commercial HVAC efficiency boosting
  • Industrial refrigeration pre-cooling
Exhaust Plume Suppression

Hot Exhaust Recirculation Is Reducing Your Efficiency.

When condenser discharge air recirculates back into the inlet, a common problem in rooftop and plant room installations, it compounds inefficiency in a feedback loop. youmist plume suppression systems atomise mist directly into the hot discharge airstream, cooling and dispersing the exhaust plume before it can recirculate. This also eliminates the visible vapour plume from condenser discharge, addressing neighbour concerns and building aesthetic requirements at commercial and mixed-use sites.

HVAC pre-cooling condenser misting installation
Case Study · HVAC Pre-Cooling · Sydney

Oran Park
Condenser Pre-Cooling System

Commercial Facility · South-West Sydney

A commercial facility at Oran Park required a solution to improve the performance of its HVAC condenser units during Sydney's peak summer periods, when the system faced maximum load at the highest ambient air temperatures.

youmist designed and installed a high-pressure pre-cooling system at the condenser coil inlets, atomising ultra-fine mist into the incoming airstream to reduce inlet air temperature during peak load conditions. The system operates automatically during high-temperature periods, reducing compressor load and improving COP at the moments of highest energy cost. Non-wetting installation with no moisture contact with coils or electrical components.


  • Reduced condenser inlet air temperature
  • Improved HVAC efficiency during peak summer load
  • Automated operation activating on temperature threshold
  • Non-wetting with no contact with coils or components
  • Reduced energy costs during peak demand periods

Ready to Extend Your Outdoor Season?

We design and install cooling systems for councils, venues and worksites across Australia.

Send an Enquiry →
Smart Controls

Set It. Forget It.
Your System Runs Itself.

Every youmist cooling system can be configured to operate automatically, no manual switching, no oversight required.

Temperature Triggered

Activates automatically when ambient temperature reaches your set threshold (e.g. 28°C, 32°C) and shuts off when conditions cool. No manual intervention needed.

Timer Scheduling

Programmable digital cyclic timer. Set active hours to match peak usage periods. Operating cost is minimised by ensuring the system only runs when the space is in use.

Weather Station Integration

Advanced installations can integrate with on-site weather stations, responding to temperature, humidity and wind conditions in real time for optimal performance and water efficiency.

Web & App Monitoring

Remote monitoring via web dashboard or mobile application. View system status, adjust settings and receive fault alerts from anywhere. Available on all multi-zone installations.

FAQ

Common Questions

No. youmist systems operate at over 1,000 PSI, atomising water into droplets of just 5–10 microns. At this size, droplets flash-evaporate on contact with hot air before reaching surfaces or people. The result is a cooling sensation without moisture, no wet clothes, no slippery surfaces and no runoff.

A standard single-phase pump installation costs under $3.50 per day in combined power and water usage, making high-pressure misting one of the most cost-effective outdoor cooling methods available. Multi-zone or larger installations will vary, and we provide detailed running cost estimates as part of every proposal.

Yes. All youmist systems can be configured with temperature-triggered automation, programmable timers, or both. The system activates when your set temperature threshold is reached and shuts off automatically when conditions cool. No manual switching, no oversight required.

Yes. youmist works regularly with landscape architects, urban designers and civil engineers on council precinct and public realm projects. We provide specification documentation, drawings and technical support for inclusion in landscape architecture packages. Flush-mount ground systems and catenary line configurations are frequently specified for civic and public space projects.

youmist systems are designed for low maintenance in Australian conditions. Nozzle filters should be checked and cleaned periodically, and annual servicing of the pump unit is recommended. We offer maintenance and SLA packages for councils, venues and commercial operators who prefer a fully managed service.